http://www.astm.org/Standards/C1208.htm
C1208/C1208M-99a Standard Specification for Vitrified Clay Pipe and Joints for Use in Microtunneling, Sliplining, Pipe Bursting, and Tunnels
http://www.astm.org/Standards/D1784.htm
D1784-99a Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds
http://www.astm.org/Standards/D5813.htm
D5813-95 Standard Specification for Cured-In-Place Thermosetting Resin Sewer Pipe
http://www.astm.org/Standards/F1216.htm
F1216-98 Standard Practice for Rehabilitation of Existing Pipelines and Conduits by the Inversion and Curing of a Resin-Impregnated Tube
http://www.astm.org/Standards/F1504.htm
F1504-02 Standard Specification for Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer and Conduit Rehabilitation
http://www.astm.org/Standards/F1533.htm
F1533-97 Standard Specification for Deformed Polyethylene (PE) Liner
http://www.astm.org/Standards/F1606.htm
F1606-95 Standard Practice for Rehabilitation of Existing Sewers and Conduits with Deformed Polyethylene (PE) Liner
http://www.astm.org/Standards/F1697.htm
F1697-96 Standard Specification for Poly(Vinyl Chloride) (PVC) Profile Strip for Machine Spiral-Wound Liner Pipe Rehabilitation of Existing Sewers and Conduits
http://www.astm.org/Standards/F1741.htm
F1741-96 Standard Practice for Installation of Machine Spiral Wound Poly (Vinyl Chloride) (PVC) Liner Pipe for Rehabilitation of Existing Sewers and Conduits
http://www.astm.org/Standards/F1743.htm
F1743-96 Standard Practice for Rehabilitation of Existing Pipelines and Conduits by Pulled-in-Place Installation of Cured-in-Place Thermosetting Resin Pipe (CIPP)
http://www.astm.org/Standards/F1867.htm
F1867-98 Standard Practice for Installation of Folded/Formed Poly (Vinyl Chloride) (PVC) Pipe Type A for Existing Sewer and Conduit Rehabilitation. This practice covers the procedures for the rehabilitation of sewer lines and conduits 4 in. (102 mm) to 18 in. (457 mm) in diameter by the insertion of a folded/formed PVC pipe that is heated, pressurized, and expanded to conform to the wall of the original conduit forming a new structural pipe-within-a-pipe. This rehabilitation process can be used in a variety of gravity applications such as sanitary sewers, storm sewers, and process piping.
http://www.astm.org/Standards/F1947.htm
F1947-98 Standard Practice for Installation of Folded Poly (Vinyl Chloride) (PVC) Pipe into Existing Sewers and Conduits
http://www.astm.org/Standards/F1962.htm
F1962-99 Standard Guide for Use of Maxi-Horizontal Directional Drilling for Placement of Polyethylene Pipe or Conduit Under Obstacles, Including River Crossings